50
LATCH KEY
If the Latch Key function is enabled and the
system is disarmed by a user that is enabled for
Latch Key then…
1. The first Latch key phone number will be called
(if entered).
2.
10s after the number is dialled the appropriate
User ID message will be replayed.
The appropriate user ID message will be repeated
continuously for 60s. After 60s has elapsed the
current message play cycle will be completed and
then the call will be terminated. This ensures the
message is not cut off part way through.
3.
There is a 10s delay before the second latch
Key phone number is dialled (if entered).
4.
After both entered numbers have been dialled
once. There will be a 30s delay before the next
call sequence is started again from the first
entered number.
The dialler sequence can be stopped early by either…
a. All numbers have been dialled three times
b. A call is acknowledged by the recipient
pressing the button on the telephone
keypad.
ZONE LOCKOUT
If while the system is armed a single alarm zone
triggers an alarm more than three times and zone
lockout is enable then the particular zone will be
“locked out” and any further alarm signals from that
zone will be ignored by the siren and an alarm will
not be triggered again during that armed session.
The zone lockout will be cancelled when the siren
is disarmed.
If zone lockout is disabled then there is no limit to the
number of alarms that any single zone can initiate.
Zone lockout is applicable to Alarm zones only. It
does not operate with the Fire zone.
DEVICE TAMPER
The Tamper zone operates on a 24 hour basis.
(i.e. Receipt of a Tamper signal form any device
will immediately trigger an alarm irrespective of
systems armed/disarmed status unless the system
is in program or Test modes).
If the battery cover of any device (except a Remote
Control) is removed or if the Siren or Control Panel
are removed from the wall then an alarm will
immediately occur (unless the system is in Test or
Program modes), even if the system is Disarmed.
The Alarm will sound until the set alarm duration time
expires or the system is Disarmed from the Remote
Control or Keypad. The ‘ALARM MEM’ LED on the
Control Panel will flash and the panel will beep every
few seconds to indicate an alarm has occurred.
CHIME
The Chime facility can only be operated with the
system in Standby mode.
Press to toggle the Chime facility between ON
and OFF.
Also see page 39 in Zone Setup menu, 3.7 Znn
Chime to enable the required zone.
KEYBOARD BEEP MUTE
The keyboard beeps can be temporarily switch
on/off by pressing
.
ENTRY/EXIT BEEPS
If the entry/exit delay beeps are enabled then they
may be temporarily switched OFF during the active
delay period only by pressing
.
When the next entry/exit delay periods starts the
beeps will follow the main system setting as normal.
EVENT LOG
Any new event entered into the event log will be
indicated by the ‘Alarm Msg’ LED flashing every
5 seconds.
Note: Alarm events only will cause the panel to
beep every 10s, other system events entered into
the event log (e.g. low battery) will not initiate the
warning beeps.
Comentarios a estos manuales