Response SL5 Manual de instrucciones Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20
6. Activate the Tamper Switch on the MAG
detector.
If the detector is new and not already linked on
any security zone the panel will produce two
short beeps and the display will show ‘New
Device’ and the type of device detected (MAG).
7. Confirm the new device ID code by activating
the Tamper Switch on the same new MAG
detector within 15 seconds.
The panel will produce three short beeps and
the LCD will show ‘Device Confirmed’.
The LCD will then show ‘Saving New Device’
while the ID code of the new detector is stored
into memory.
8. Refit the battery cover.
9. After completing the Zone Setup press to
return to the top level of programming menu.
TESTING A MAGNETIC DOOR/WINDOW
DETECTOR WITH THE CONTROL PANEL
1. Ensure that the system is in Test Mode (see
page 13).
2.
Use the and buttons to scroll through
the menu until ‘Detector Walk Test’ is displayed
and press .
will be displayed.
Note: If no signal is received by the Control Panel
within 10 minutes, the display will return to ‘Detector
Walk Test’
.
3.
Open the door/window to remove the Magnet
from the Detector.
In addition, the Control Panel will beep to
indicate that the alarm signal has been received
and the identity of the zone that the detector is
configured for will be displayed.
4.
Remove the battery cover. The Control Panel
should beep and display:
to show that the detector’s tamper switch has
been activated.
5.
Refit the battery cover.
6.
Press to exit Test Mode and return to
standby.
IMPORTANT: With the battery cover fitted the
LED indicator will not flash when the door / window
is opened, (unless the battery is low).
Note: If the detector is already linked to the
control panel on any other zone then the
panel will produce a single long beep and
the received signal from the detector will
be ignored.
Note: If the confirmation signal is not
received within 15s the control panel will
produce a single long beep and exit the
learning process. The learning process will
need to be started again to learn the new
device into memory.
ESC
ENTER
Walktest
Waiting...
Zone X : MAG
Tamper
ESC
Vista de pagina 19