Response SL5 Manual de instrucciones Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
41
NAME
This enables a name to be allocated to the zone so it
can be identified by its location.
Available for all zones 1- 36. Only available for
wireless zones 1-32 if a detector is linked.
Default setting: No Name
Scroll through the Zone menu until ‘3.2 Zxx Name’
(and the current setting) is displayed.
To change the setting press .
Scroll through the menu options, until the
required setting is displayed.
Options: No name, Front Door, Back Door,
Side Door, Patio Door, Dining Room,
Living Room, Lounge, Study,
Play Room, Kitchen, Utility Room, Hall,
Landing, Bedroom 1, Bedroom 2,
Bedroom 3, Bedroom 4, Bedroom 5,
Shed, Garage, PIR, MAG or SMOKE.
Press to save the new setting, or
Press to exit without saving.
TYPE
Each zone may be programmed to operate in 1 of 4
different modes dependant upon the type of alarm
function required. The following types are available:
Intruder - provides standard intruder monitoring.
24 Hour Intruder - used to provide 24 hour
monitoring of areas requiring continuous security
protection even while the system is Disarmed, (e.g.
gun lockers). Activation of any detector on a
security zone will immediately initiate an Alarm.
Fire - used to provide 24 hour monitoring of any
Fire/Smoke detectors fitted to the system. Activation
of any detector will immediately initiate an Alarm.
Test - when the system is armed, any detector on
the zone will generate an entry in the Event Log
without initiating an alarm.
Default setting: Intruder
Scroll through the Zone menu until ‘3.3 Zxx Type’
(and the current setting) is displayed.
To change the setting press .
Scroll through the menu options, until the
required setting is displayed.
Press to save new setting and exit, or
Press to exit without saving.
ZONE MODE
Each zone may be selected to operate with or
without a entry/exit delay period (see System Setup
menu). This is selected in zone mode.
Default setting: Zones 1- 2: Delayed
Zones 3-36: Instant
Available for all zones 1- 36. Only available for
wireless zones 1-32 if a detector is linked
Scroll through the Zone menu until ‘3.4 Zxx Mode’
(and the current setting) is displayed.
To change the setting press .
Scroll through the menu options, until the
required setting is displayed.
Options: Instant / Delayed
Notes: Smoke detectors can only be
set as Instant
Press to save new setting, or
Press to exit without saving.
PART-ARM 1
This controls whether the zone is active when
Part-Arm 1 is armed.
Default setting: Zones 1- 4: ON
Zones 5-36: OFF
Scroll through the Zone menu until ‘3.5 Zxx Part-Arm 1’
(and the current setting) is displayed.
To change the setting press .
Press to enable the zone in part arm 1, or
Press to disable the zone in part arm 1.
ENTER
ESC
ENTER
ESC
ENTER
ESC
ENTER
ENTER
ENTER
1
3
ENTER
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 63 64

Comentarios a estos manuales

Sin comentarios