25
(Optional)
The Control Panel incorporates a terminal block for
connection of a Hard-wired Siren. The connection
terminal block is located inside the Control Panel
behind the front cover. To access the terminal block
you must first put the system into Test Mode to
prevent an alarm occurring.
To do this:
Press
Undo the two fixing screws on the top edge of the
Control Panel and open the front cover.
Before making any connections, ensure that the
Reset Jumper Link P1 is in the ‘OFF’ position and
then remove the DC power jack and disconnect 1 of
the back-up batteries.
The signalling contacts on all hardwired alarm and
tamper zones must be volt free. (i.e. they must only
open and close and not apply any self generated
voltage across the contacts).
The contacts on zones 33, 34, 35 and the tamper
circuit should be normally closed. An alarm will be
triggered when the contacts open. On zones 33, 34
and 35, additional Wired Magnetic Door/Window
Contact Detectors can be hardwired to these
terminals (by purchasing the Response Wired
Door/Window Contact Accessory Pack (PW1).
The contacts on zone 36 should be normally open.
An alarm will be triggered when the contacts close.
Note: The External Tamper Switch jumper link P51
should be fitted into the ON position only if the
hardwired tamper circuit is used, otherwise it must
be in the OFF position.
After making your external connections reconnect
the power supply and back-up Battery. Then close
the Control Panel cover and tighten the fixing
screws on the top edge.
Press to leave Test Mode and return to Standby.
EXTERNAL CONNECTIONS
N.C.
N.O.