PROGRAMMING
Scroll through the programming menu until ‘3. ZONE
SETUP’ is displayed and press .
Enter the zone number to be configured and press
.
The following configuration options are based upon
configuring zone 1. Options for all other zones (2-10)
are identical except the zone number reference will
change according to the zone being configured.
Note: After completing the Zone Setup press
to return to the top level programming menu.
NAME
This enables a name to be allocated to the zone so it
can be identified by its location.
Default setting: ‘No Name’
Scroll through the menu until ‘3-1 Z01 Name’ (and the
current setting) is displayed.
To change the setting press .
Scroll through the menu options until the required
setting is displayed.
Press to save and exit, or
Press to exit without saving.
TYPE
Each zone may be programmed to operate in one of 5
different modes dependant upon the type of alarm
function required. The following types are available.
Panic/PA
- used to provide 24 hour monitoring of any Personal
Attack (PA) switches fitted to the system. Activation
of any PA switch will immediately initiate an alarm.
Intruder
- provides standard intruder monitoring.
ZONE SETUP
The parameters in this menu allow each zones specific function to be configured.
3-4 Zxx Chime
xxx
3-1 Zxx Name
xxxxxxxxxxxx
3. ZONE SETUP
PROGRAM MODE
Code:
Select
ON->1 OFF->3
Enter Zone(1-10)
No Name
Front door
Back door
Patio door
Dining room
Living room
Lounge
Kitchen
Shed
Hall
Landing
Upstairs
Downstairs
Bedroom 1
Bedroom 2
Bedroom 3
Bedroom 4
Windows 1
Windows 2
Windows 3
PIR Detector
Magnetic Contact
FIRE/SMOKE
Panic/PA
3-2 Zxx Type
xxxxxxxxxxxx
Panic/PA
Intruder
24 Hour Intruder
Fire
Test
select menu item
…press ENTER
select menu item
…press ENTER
3-3 Zxx Final
Exit Set: xx
Select
ON->1 OFF->3
3-6 Zxx
Part-Arm 1: xxx
Select
ON->1 OFF->3
3-5 Zxx ENTRY
DELAY: xxx xxxs
3-5-1 Status:
xxx
Select
ON->1 OFF->3
3-5-2 Delay Time
Enter (10-250s)
3-8 Zxx Walk
Through: xxxxxx
3-7 Zxx
Part-Arm 2: xxx
Select
ON->1 OFF->3
Enter (10-250s)
Off
Slave
Master
select menu item
…press ENTER
28 SA5
ENTER
ENTER
ENTER
ENTER
ESC
ESC
Vista de pagina 29