13
4. If an additional wired Magnetic Contact is required,
this should be wired to the terminal block provided in
the battery compartment. The wired contact should be
connected using a maximum length of 1.5 metres of
any of the following:
- 6 core alarm cable
- 2 core bell wire (6 x 0.2mm minimum)
- 2 core 24AWG wire
A cable entry cut-out is provided beside the terminal
block in the battery cover.
If an additional wired contact is connected to the
detector then jumper Link S2 on the Circuit board must
be removed.
IMPORTANT: If an additional wired contact is not
connected, then the Jumper Link S2 must be tted
for the Detector to operate correctly.
5. Congure the House Code for the Magnetic Contact
Detector by setting DIP switches 1-8 to the same ON/
OFF combination as the House Code DIP switches in
all other system devices.
7. Slide the two batteries supplied into the battery
holder, ensuring that the + side is uppermost on each
battery as it is installed.
8. If necessary, ret the battery holder into the Detector
ensuring that the spring clip connectors slide onto
either side of the circuit board.
9. Ret the battery cover.
Testing the Magnetic Contact Detector:
10. Remove battery cover to activate the tamper switch.
As the button is released the LED indicator will
illuminate for approximately 1 second to show that the
tamper switch has been triggered and a signal is being
transmitted.
11. Open the door/window to remove the Magnet from
the Detector.
As the Magnet is moved away from the Detector the
LED indicator will illuminate for approximately 1 second
to show that the Detector has been triggered and a
signal is being transmitted.
Note: It does not matter if the LED indicator illuminates
as the magnet is brought towards the detector.
12. Ret the battery cover.
EXTERNAL SOLAR SIREN
The Siren is encapsulated within a tough polycarbonate
housing that also provides full protection against
adverse weather conditions.
An LED indicator unit is built into the Siren to act as
a visible deterrent and indication that the system is
active. The LEDs will slowly and alternately ash
whether the system is Armed or Disarmed. When the
alarm triggers the LEDs will ash rapidly together.
An integral tamper switch provides additional security
protection to the Siren and will immediately trigger an
alarm should any unauthorised attempt be made to
interfere with and remove the siren cover, (unless the
Siren is in Service Mode).
ON
1
2 3 4 5 6 7 8 9 10 11 12
6. DIP Switches 9-11 must be set as follows for use
with this alarm system:
DIP 9 DIP 10 DIP 11
ON ON OFF
Comentarios a estos manuales