24 RE5000S Professional Alarm System
TROUBLE SHOOTING
Control Unit will not arm. Control Unit
emits 3 bleeps when trying to arm.
1. Magnetic Contact Detector Open - Check Zone
LED illuminated and close detector(s) on that Zone.
If Detector cannot be closed, enter, then exit
Programming mode to clear the indication.
2. Low battery in a Detector. Check Zone indicated,
change battery and clear indication at Control Unit.
3. Alarm/low battery indicator not cleared. Enter Main
User or Second User Access Code followed by .
Detection Zone has been triggered but no
alarm is sounding
1. Entry delay zone triggered - alarm will sound when
delay time has expired.
2. Zone omitted when part armed.
3. Silent alarm option selected.
Control Unit ‘Low Battery’ light flashing,
Zone LED(s) flashing and control unit
bleeping every 60 seconds
1. Check all PIR Detector(s) on the Zone indicated for
low battery, indicated by detector LED flashing when
movement is detected - change battery(s) as
required.
2. Check all Magnetic Detectors on the Zone indicated
for low battery indicated by detector LED not
illuminating when detector is opened/closed -
change battery(s) as required.
3. Check the battery in all RE5000 Smoke Detectors -
a low battery will also cause the Smoke Detector to
bleep every minute - change battery as required.
Full Alarm Occurs when alarm has not been
activated by an intruder
1. Ensure mains adaptor is plugged in/connected and
switched on.
2. Ensure that the Control Unit is securely fitted to the
wall and that the rear battery compartment cover is
closed.
3. Check that Personal Attack Button, Medical Alert
Pendant or Smoke Detectors have not been
operated.
4. Check that battery covers on all detectors are fitted
securely.
5. Check for Jamming Detection Alarm operation.
Control Unit not working. Mains light is off.
1. Check that mains adaptor is plugged in/connected
and switched on.
Control Unit will not function
(Sirens are sounding)
1. Disconnect power (including Control Unit back-up
battery), for 10 seconds, then re-connect mains
power followed by back up battery. (Remember, all
programmed functions will be retained if the Memory
Link is in the ON position).
Control Unit not accepting access code(s).
1. Pausing too long between pressing keys. Do not
pause for more than 5 secs between keys.
2. Incorrect code entered. Allow 5 seconds to elapse
before re-entering correct code.
3. Unit has reset to factory default codes/programme.
Fit Memory Link in ON position and re-programme
all programmable features.
Control Unit emits two-tone chime when
detectors are triggered.
1. Door-Chime set to operate on Magnetic Detector
Zone(s) - Re-programme Door-Chime Zone(s).
2. Control Unit in Test mode - Reset to normal,
disarmed mode.
Control Unit not responding to detectors.
1. Ensure detectors are within radio range of Control
Unit. If not, move detector closer.
2. Ensure that the House Code on the Detector is the
same as that set in the Control Unit.
3. Replace detector battery.
Solar Siren and Strobe sounding but no
alarm at Control Unit.
1. Siren Anti-tamper activated. Check security of
Siren/Strobe fixing to wall and that Siren anti-tamper
switch is fully depressed.
2. Siren & Strobe has not received Stop signal.
Press Disarm on Remote Control to make the
Control Unit re-transmit the Stop signal.
Symptom
/
Recommendation Symptom
/
Recommendation