5. Hold the Contact Detector at the correct position
on the door or window, then press and release the
anti-tamper switch. Providing the Detector is
within radio range of the Control Unit, the two-tone
chime will be repeated, for another 3 seconds.
When fitting the detector to a metal door or
window, under exceptional circumstances, it
may be necessary to space the Magnet/
Detector off the metal surface using a plastic
or wooden spacer to achieve the necessary
radio range.
6. Remove the battery, then using the double
sided tape OR the screws provided, mount the
magnet to the door and the Detector to the
door frame (or vice-versa, if required). Ensure
that the arrow on the Magnet lines up with the
line on the Detector and that the gap between
the Detector and the Magnet is less than 5mm.
When using the screws for mounting the
Detector, ensure that the small countersunk
screw is used within the battery compartment
and that the screw is driven flush with the
inside of the casing.
7. Refit the battery and battery cover. (The two-
tone chime sound will be repeated at the
Control Unit).
8. Test the operation by opening and closing the
door/window. The red LED on the Detector will
illuminate for approximately 1 second and the
Control Unit will emit a two-tone chime each
time the detector is opened and closed.
Note: In addition to the Standard RE5000M Magnetic
Detector, the RE5000MHW Detector is available and
incorporates facilities to accept hard-wired normally
closed and normally open circuit inputs, in addition to
the standard Contact Detector operation. Refer to
page 27 for further details.
Once you have completed installing all your
Detectors, take the Control Unit out of Test mode
by pressing and holding the button until the
Control Unit emits 2 bleeps and the Arm/Disarm
LEDs extinguish.
INSTALLING AND
SETTING THE EXTERNAL
SOLAR WIRELESS SIREN
& STROBE
The Solar Siren & Strobe Unit should be fitted to the
outside of the building in a position that is clearly
visible and at a height which is relatively
inaccessible to an intruder.
The Solar Siren & Strobe incorporates a solar panel
which will maintain a charge to the integral 6V 1.2Ahr
sealed lead acid rechargeable battery during daylight
hours. During the night a negligible amount of energy
is released by the rechargeable battery to operate the
Siren & Strobe. The Solar Siren & Strobe is self-
maintainable during darkness and long winter periods.
LOCATION
To provide the optimum amount on daylight to the
Solar Panel, you should ideally mount the Solar
Siren & Strobe on a south facing wall. However, an
easterly or westerly position will suffice.
Although the Solar Siren & Strobe is designed to work
on any aspect wall, for optimum performance you
should refrain from siting the unit on a north facing wall
where possible. Shadows cast by neighbouring walls,
trees and roof overhangs should also be avoided.
Where applicable, the Solar Siren & Strobe should be
positioned a minimum of twice the width of the eaves
overhang below the eaves. Remember that in winter
the sun is lower in the sky and you should avoid winter
shadows where possible.