20
4. DIP switch 1 marked “ALARM TIME” is used to
limit the maximum period for which the external
siren will sound before it will be automatically shut
down, (even if the Control Panel is still in alarm):
ON 10 minutes
OFF 3 minutes
5. DIP switch 2 marked “AJ” does not function for
this system and should be ignored.
6. DIP switch 3 marked “ALARM SOUND” if OFF
will prevent the siren from sounding during an
alarm, (this will not affect the warning beeps):
ON Siren enabled
OFF Siren disabled
7. Switching between Service Mode and Operating
Mode generates a series of beeps. It is possible
to disable these acknowledgement beeps with
DIP switch 4 marked “BEEP SOUND”.
ON Beeps enabled
OFF Beeps disabled
8. Now see Power-Up of the Solar Siren.
POWER-UP OF THE SOLAR SIREN
Note: The use of ear defenders is advisable when
working in close proximity to the Siren due to the high
sound level produced by this device when triggered.
Whenever the Siren is powered-up, it will automatically
power-up in Service Mode. It cannot be switched out
of Service Mode and into Operating Mode until the
Control Panel is linked to it.
9. Connect the rechargeable battery to the battery
leads. Connect the Red lead to the Red (+ve)
terminal and the Black lead to the Black (
-
ve)
terminal.
Connect the 9V 6LR61 (PP3) power-up battery
to the battery clip.
10. Press the tamper switch, both indicator LEDs will
flash together several times. The LEDs will then
continue to flash alternately every 5 seconds
thereafter to indicate that the Siren is functioning
(still in Service Mode).
11. If fitted remove the protective film covering the
Solar Panel.
12. Now follow the instructions on the next page to
Link the Solar Siren to the Control Panel.
Siren
7.5 Volt DC
charging
adaptor input
ALARM TIME
A J
C.U. OR SIREN
ALARM SOUND
BEEP SOUND
Learn
LED
ON
1
2 3 4 5
ALARM TIME
A
J
ALARM SOUND
B
EEP SOUND
C.U. OR SIREN
ON
1
2345
ALARM TIME
AJ
ALARM SOUND
BEEP SOUND
C.U. OR SIREN
Tamper
Switch
Learn
Switch
Switch SW3
9 Volt startup
battery
6 Volt 1.2Ah
rechargeable
battery
Wall mounting plate
IMPORTANT: Once the batteries have been
connected, the Siren will be operational and it is
important that the solar panel receives sufficient
light to maintain the battery charge. The Siren
should not be operated repeatedly during
installation and testing, as this will rapidly drain
the battery. It is recommended that the Siren be
left for at least a day in order to charge the
battery before the system is Armed.