38
1
.
Dial up the system and hang up after two
rings.
2
. Redial up the system within 30s, the system
will pickup the phone after 1 ring.
3
. Enter the User Access code as normal.
The following functions may be access via the
remote. The system will acknowledge each signal
w
ith a single long beep.
Press to initiate ARM.
Press to initiate Part-Arm 1.
Press to initiate Part-Arm 2.
Press to Disarm the system.
Press to turn the Siren OFF.
Press to turn the Siren ON.
Press to Listen-In via the Control Panel
Microphone.
Press to stop Listen-In
Note: Listen-In will be automatically cancelled
after 5 minutes if not cancelled manually.
Press to interrogate the system Status. The
status tone will be repeated at 2s intervals for 15
seconds.
One beep ARM
Two beeps Part-Arm (1 or 2)
Three beeps Alarm triggered
One long beep Disarmed
Press to replay Answer-Phone messages.
While replaying a message, press for
2 seconds to skip to the end of the message
and hear the next message.
Press
to delete all Answer Phone messages.
Press to end the session and Hang up the
Control Panel line.
Battery Monitoring
All system devices continuously monitor their battery
c
ondition. The Control Panel also monitors the battery
condition of all PIR and Magnetic Detectors. If the
battery level of any device drops below acceptable
l
evels then its low battery indication will be activated.
In addition if any PIR or Magnetic Contact Detector
has a low battery status it will be indicated on the
‘
LOW BAT’ LED on the Control Panel.
LED Glowing Magnetic Contact
LED Flashing PIR
When a low battery indicator is activated the device
will continue to operate normally for up to 2 weeks
(depending on system use). However, the battery for
that device should be replaced as soon as possible.
Note: Before removing the battery cover on any device
to replace the battery, ensure that the system is put
into Test mode to avoid initiating a Full Alarm condition.
The low battery indication for each system component
is as follows:
Remote Control:
When the Remote Control is operated under low
battery conditions the transmit LED will continue to
flash after the button has been released.
Under normal battery conditions the LED will extinguish
when the button is released.
PIR Movement Detector:
Under low battery conditions the LED behind the
Detector lens will flash when movement is detected to
indicate that the battery needs to be replaced.
Under normal battery conditions the LED does not
illuminate unless the PIR Detector is in Walk Test mode.
Magnetic Contact Detector:
Under low battery conditions, when the Detector is
activated, the transmit LED will be illuminated for
approximately 1 second as the door/window is
opened.
Under normal battery conditions the LED will not
illuminate as the Detector is operated, (unless the
Detector is in Test Mode with the battery cover
removed).